High Temperature IP67 Vent Plug - China Suppliers & Factory - Breathable Pressure Equalizing for Packaging Vents

,

PRODUCT NAME: Snap-In Vent Plug

,

PRODUCT MODEL: Vent Plug_D15_E1W09

,

Important Note:

,

The information provided above represents typical data for the membrane raw material and is intended for reference purposes only. It should not be regarded as specific data for outgoing quality control.

,

All technical details and recommendations are based on Zzpip’s extensive experience and testing. While Zzpip strives to provide accurate information, it assumes no legal responsibility for its use. Customers are encouraged to verify the compatibility and performance of the product for their specific applications, as the effectiveness can only be assessed when all relevant operational data is considered.

,

As a leading manufacturer and supplier of vent plugs in China, Zzpip focuses on delivering high-quality products that meet diverse industrial needs. Our factory employs advanced processes to ensure that our Snap-In Vent Plug performs reliably in various environments.

,
Request a Quote

PRODUCTS DETAILS

Product Attributes

PRODUCT NAME Snap-In Vent Plug
PRODUCT MODEL Vent Plug_D15_ZZPIP-E1W09
MEMBRANE MODEL ZZPIP-E1W09
APPLICATION FIELD Chemicals Packaging
APPLICATION CHEMICAL Bleacher, Disinfectant, Amino Acid, Agrochemicals, Live bacterial agent, Thick liquid fertilizer
Product Diagram - Vent Plug D15

Product Properties

Physical Properties Referred Test Standard Unit Typical Data
Plug Material / / HDPE
Plug Color / / White
Membrane Construction / / PTFE/PO non-woven
Membrane Surface Property / / Oleophobic & Hydrophobic
Typical Air Flow Rate ASTM D737 ml/min @ 7KPa 700
Water Entry Pressure ASTM D751 KPa dwell 30 sec ≥ 80
IP Grade IEC 60529 / IP67 / IP68
Moisture Vapor Transmission ASTM E96 g/m2/24h > 5000
Oleophobic Grade AATCC 118 Grade ≥ 7
Service Temperature IEC 60068-2-14 °C -40°C ~ 125°C
ROHS IEC 62321 / Meet ROHS Requirements
PFOA & PFOS US EPA 3550C & US EPA 8321B / PFOA & PFOS Free

Application & Instructions

This series of vent plug could equalize the pressure differentials of chemical containers which caused by temperature difference, altitude changes and releasing/consuming gases, in order to prevent container deformation and liquid leakage.

The vent plugs can be used in breathable cap products for chemicals packaging containers, and be suitable for High-concentration Hazardous Chemicals, Low-concentration Household Chemicals, Agricultural Chemicals and other Special Chemicals.

Shelf Life

Shelf life is two years from the date of receipt for this product as long as this product is stored in its original packaging in an environment below 80°F (27°C) and 60% RH.

Technical Note & Disclaimer

All data above are typical data for the membrane raw material, for reference only, and should not be used as special data for outgoing quality control.

All technical information and advice given here is based on ZZPIP’s previous experiences and test results. ZZPIP gives this information to the best of its knowledge, but assumes no legal responsibility. Customers are asked to check the suitability and usability in the specific application, since the performance of the product can only be judged when all necessary operating data are available.

Frequently Asked Questions (FAQ)

Q1 What is the main function of this Snap-In Vent Plug?

It is designed to continuously equalize internal pressure differentials in chemical containers caused by altitude fluctuations, temperature shifts, and outgassing/gas consumption, thereby preventing container collapse, bloating, or liquid leakage.

Q2 What types of chemicals are compatible with the ZZPIP-E1W09 vent plug?

It is suitable for a wide range of liquids including bleachers, disinfectants, amino acids, agrochemicals, live bacterial agents, thick liquid fertilizers, and other high or low concentration chemical formulations.

Q3 What are the membrane surface properties and ingress protection (IP) ratings?

The membrane features PTFE/PO non-woven construction with oleophobic (Grade ≥ 7) and hydrophobic characteristics, providing robust liquid barrier protection certified to IP67 and IP68 standards.

Q4 What is the operating temperature range for this vent plug?

The vent plug is engineered to maintain full operational integrity in extreme service temperatures ranging from -40°C to 125°C (tested under IEC 60068-2-14).

Q5 Does the product comply with environmental and hazardous substance standards?

Yes, the vent plug meets all RoHS requirements (IEC 62321) and is verified to be completely PFOA & PFOS free in compliance with US EPA 3550C & US EPA 8321B testing methods.

Q6 How should the vent plug be stored to maintain its 2-year shelf life?

To ensure its 2-year shelf life from the date of receipt, the product must be kept in its original packaging at temperatures below 80°F (27°C) and relative humidity below 60%.

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours

Leave YourMessage

Thank you! We will reply you via email within 24 hours.

Return